Description SPX has developed a fully automatic service station for an accurate discharge/recharge of CO
2 Mobile Air Conditioning systems.
Basic Specifications
- Max. operating pressure: 10 Mpa
- Safety switch / Pressure relief: 10 Mpa and/or Pressure gauge
- Pressure gauges: electronic transducers
- Solenoid block: yes, production version only
- Oil separation & drain: yes, to be defined
- Vacuum pump: dual stage 180 lt/min, 50 microns
- Oil injection: minimum 1 ml measuring resolution
- Tank capacity: 5 kg + external tank
- Regulated tank heater
Advantages
- Usability: full automatic control to avoid operator presence; guided software; integrated database; printer
- Accuracy: controlled discharge & recharge of the system (oil & refrigerant); refrigerant charging controlled by an electronic scale with an accuracy of at least +/- 5g (1.25% at 400g); CO2 recovery flow rate will be limited to prevent freezing and explosive decompression
- Vacuum: evacuation and moisture removal; electronic leak detection under vacuum
- Safety: safety pressure relief devices on key points; secured connection to vehicle service ports; heated tank controlled; automatic vehicle pressure detection alarm; complies with EU norms / SAE & UL standards
- Monitoring: constant monitoring of pressures and temperatures on LCD and/or graphic display (HP & LP, ambient temperature, air vent temperature)