Description:
The microprocessor-based Control Box controls the compressor mass flow based on the required temperature or pressure value. It was designed to operate only with the C99 externally controlled compressor. The compressor is equipped with a low pressure sensor and a combined discharge pressure and temperature sensor.
Basic specifications
- Intergrated safety loop for:
- Discharge pressure
- Discharge temperature
- Suction pressure
- AC, Heat Pump (HP) and Hot Gas (HG) mode implemented
- AC Mode control value (selectable):
- Temperature air after evaporator
- Suction pressure
- HP Mode control value: temperature air after evaporator
- HG Mode control value: discharge pressure
- Freely adjustable PID controller for all control loops:
- Manually adjustable on the box
- Externally adjustable with interface
- Output channel for switching valve signal
- Power supply: 12VDC (automotive)
- Size: 125mm x 105mm x 40mm
- The control box includes 2 sets of cables to connect the control box with the compressor (Control valve, LP-Sensor; HPT Sensor) and the power supply and external interface.