Wal-Mart Canada has opened its first environmental demonstration store in Burlington, Ontario. Among many sustainable features, the store encompasses a CO2 refrigeration system, whereby the heat from the system is captured and reused to heat the store.
Wal-Mart Canada opens store using CO2 refrigeration
On 16 January, Wal-Mart announced the opening of the first environmental demonstration store in Canada, to serve as a blueprint for a series of stores the company plans to roll out within 2009. Each of the series stores is set to achieve energy efficiency improvements of at least 30 per cent compared to the company’s typical stores. The Burlington supercentre store is expected to even exceed this minimal energy savings, using an estimated 60 per cent less energy than the company’s typical store of equivalent size and reducing carbon emissions by about 141 tonnes.

CO2 refrigeration contributes towards achieving 60% energy savings

The 129,000 square feet store incorporates a CO2 refrigeration system supplied by U.S. manufacturer Hill PHOENIX. The low-temperature CO2 secondary coolant system with a medium-temperature glycol secondary system uses water-cooled condensers on the high-side to achieve more than 80% charge reduction.

Talking to R744.com, David Hinde, Research and Development Manager of Hill PHOENIX, affirms that "[Hill PHOENIX is] excited to be part of this project that combines so many innovative features, including the refrigeration system which achieves new levels of charge reduction."
To provide further energy savings, the waste heat from the refrigeration system is captured and reused to heat the rest of the store. At night, both refrigerator and freezer cases can be covered to lock in the cool temperatures and are equipped with motion activated LED lights to save energy during the day.

Other technologies used to achieve the 60% reduction in energy use are primarily related to heating and cooling needs of the store. These include:
  • Geothermal heating and cooling technology: First-of-its-kind demonstration of geothermal heating and cooling technology in a large-scale Canadian retail operation
     
  • In-floor heating and cooling system: In-floor radiant heating and cooling system circulates water to transfer heat and cold instead of air vents, requiring less electricity
     
  • Roof insulation: Increased insulation on the roof reduces heat and cooling loss
     
  • Sunlight deflecting roof: White roof membrane deflects sunlight by an estimated 85 per cent to reduce heat gain in summer and demand on the electrical grid
The list of carbon saving features is finally completed by using means of enhancing the natural illumination of the store, sensors that assess the need for artificial illumination and 100% renewable sources to power the store.

About Wal-Mart Canada

Headquartered in Mississauga, Ontario, Wal-Mart Canada Corp. operates 316 retail outlets in Canada. Leading global retailer Wal-Mart is committed to reaching a day when every new store is 30 percent more energy-efficient than it was in 2005 and making existing stores 20 percent more efficient by 2012.
More Information
Related Keywords
 
Comments
 
First Name
Last Name
Email
(If you wish to receive notifications of new comments, please enter your email)
Anonymous
(If you check this box, your name and email will be hidden)
Post a comment: (Please do not add any links)
2009-02-05 23:12:51 - R744.com Team
Dear Fabricio,

Please register as a member of R744.com (go to the 'MyR744.com' section on the top right hand side of the website) . It is FREE and will take you two minutes. Once you have registered you will be able to choose the news you wish to receive about CO2 whether on a daily basis or a weekly basis.

Your R744.com TEAM
2009-02-05 20:30:36 - FABRÍCIO NASCIMENTO
I would like to receive news about CO2.
2009-02-01 04:11:29 - Jim Bererton
CO2 refrigeration was one of a number of measures responsible for generating the 60% reduction in energy on this trail blazing project. A major innovation was the horizontal ground field designed by Stantec Consulting of Calgary, Alberta, Canada. Transferring technology from the pipeline industry, the geo-exchange field was installed 2.2m below the parking lot. The pipeline technology reduced the installation cost by a factor of 3 in comparison with conventional excavation methods and was 6 times more cost efficient than a vertical borefield. Over 15km of piping was installed in less than 6 days using this technology.

The geo-exchange field performance is enhanced by intergration with the radiant floor system and the heat recovery from the CO2 refrigeration system.

Stantec Consulting specializes in designing alternative energy solutions using a combination of technologies including: geo-exchange, solar thermal, concentrating photo voltaic, and biomass energy systems.

For more information feel free to contact the author of this comment.

Regards,

Jim Bererton, Bsc. Eng. Physics
Sustainability Practise Lead
Stantec Consulting
© 2008 R744.com - Managed by shecco®
myR744
Username:
Password:
Remember me
Most active members
Stephen Gill
Stephen Gill
Energy Efficient Solutions
Send message
Lee jung-bu
Lee jung-bu
dae joo ent.co.ltd
Send message